Hermetically Sealed Transformers

12,499.00

Maintenance-friendly hermetically sealed transformers from 50 kVA to 5000 kVA, designed with leakage-tested corrugated tanks and ONAN cooling for reliable operation in demanding environments.

Hermetically Sealed Transformers

12,499.00

In stock
SKU: PT0003 Category:

Description

Overview

Volta hermetically sealed transformers, also known as corrugated transformers, use a sealed oil-filled tank with welded corrugated fins. The fins increase the cooling surface, support heat dissipation and form an integral part of the tank structure for mechanical strength and durability.

The sealed design eliminates the conservator and silica gel breather, preventing the insulating oil from contacting atmospheric air. This limits oxidation, sludge formation, moisture ingress and oil degradation, helping deliver reliable, virtually maintenance-free operation.

 

Technical Range

Parameter Available Range
Capacity 50 kVA to 5000 kVA
Voltage class 1.1 kV, 2.2 kV, 3.3 kV, 6.6 kV, 6.9 kV, 11 kV, 12.47 kV, 13.2 kV, 13.8 kV, 15 kV, 22 kV, 25 kV, 33 kV, 34.5 kV, 66 kV and 69 kV
Low voltage class 380 V, 400 V, 415 V, 433 V, 440 V, 600 V and 690 V
Cooling ONAN
Customisation Customised voltage classes available according to project requirements

 

Key Features

Minimal maintenance: The sealed design prevents contamination, removing the need for regular oil filtration or dehydrating breathers.

Extended lifespan: Isolation from atmospheric air slows the ageing of the insulating oil and supports a longer service life.

High reliability: Protection against moisture ingress and oil contamination reduces common causes of transformer failure.

Compact size: The design can be smaller than conventional transformers with comparable power ratings.

Suitable for polluted environments: The sealed tank helps protect internal components from dust and other pollutants.

 

Available Configurations

Construction: Sealed oil-filled tank with welded corrugated fins and MS steel construction

Capacity: 50 kVA to 5000 kVA

Voltage class: 1.1 kV to 69 kV across the published voltage-class options

Low voltage class: 380 V, 400 V, 415 V, 433 V, 440 V, 600 V and 690 V

Cooling: ONAN

Customisation: Customised voltage classes according to project requirements

Applications

Process industries: Petrochemical, pharmaceutical, textile, plastic, oil and gas plants, and refineries.

Industrial facilities: Automobile, mining, cement, heavy, steel and manufacturing industries.

Commercial and infrastructure: Hospitals, hotels, shopping malls, high-rise buildings, commercial and residential towers, tunnel projects, construction projects and highway projects.

Power and renewable projects: Hydropower, solar, wind-power, generation and transmission projects.

Description

Hermetically sealed transformers use corrugated fins welded into the MS steel tank to create an extended cooling surface. The corrugated construction helps dissipate heat, prevents overheating and contributes mechanical strength. Skilled welding and overpressure testing are used to verify the tank’s leakage resistance and structural integrity.

Unlike a conventional transformer, this design does not require a conservator or silica gel breather. The dielectric insulating fluid remains completely sealed from atmospheric air, limiting oxidation, sludge formation, moisture ingress and contamination. Reduced oil degradation supports long service life and minimal maintenance.

The available capacity range extends from 50 kVA to 5000 kVA. Published voltage classes range from 1.1 kV to 69 kV, with low-voltage classes of 380 V, 400 V, 415 V, 433 V, 440 V, 600 V and 690 V. ONAN cooling is specified, and customised voltage classes are available according to project requirements. Contact Bijali Bazaar with the required ratings and site conditions to identify the appropriate configuration.

Buyer Information Required

Capacity: Required capacity in kVA or MVA

Voltage: Required input and output voltage

Environment: Indoor or outdoor location, pollution level and ambient conditions

Tank: Required enclosure, corrugated-fin arrangement and dimensional limitations

Insulating fluid: Required dielectric fluid specification

Cooling: ONAN cooling requirement

Load: Connected load, duty profile and future expansion allowance

Standards: Applicable technical standards and project requirements