Available Configurations
Capacity: 100 kVA to 20 MVA
High voltage: 11 kV to 33 kV
Low voltage: 380 V, 400 V, 415 V, 433 V, 440 V, 600 V and 800 V
Cooling: ONAN
Tap changer: OCTC or OLTC
Customisation: Customised voltage classes and project-specific configurations
Applications
Solar power plants: Voltage conversion between solar inverter output and the grid-connection system.
Wind power stations: Voltage conversion and grid integration for wind-turbine inverter systems.
Renewable energy projects: Converter-duty service where harmonic currents and variable generation create specialised electrical and thermal demands.
Outdoor installations: Weather-exposed solar-farm and wind-power applications requiring robust enclosure construction.
Description
Solar and wind inverter duty transformers play an important role in renewable-energy systems by converting the low voltage produced by solar panels or wind turbines into a higher voltage suitable for grid connection. These converter-duty transformers are specifically engineered for the harmonic currents, thermal loading and operating conditions associated with inverter and rectifier equipment.
The available range extends from 100 kVA to 20 MVA. Published high-voltage ratings cover 11 kV to 33 kV, while low-voltage options include 380 V, 400 V, 415 V, 433 V, 440 V, 600 V and 800 V. ONAN cooling is offered, with OCTC and OLTC tap-changing options. Customised voltage classes can be developed according to project requirements.
Low-loss cores, advanced insulation and enhanced cooling provisions support efficient operation and thermal stability. Weatherproof construction makes the transformers suitable for outdoor solar-farm and wind-power installations. Contact Bijali Bazaar with the required capacity, voltage ratio, inverter details and installation conditions to identify the appropriate configuration.
Buyer Information Required
Capacity: Required capacity in kVA or MVA
Voltage: Required input and output voltage
Inverter: Solar or wind inverter output details
Load: Expected harmonic profile and loading conditions
Tap changer: OCTC or OLTC preference
Installation: Indoor or outdoor environment
Standards: Applicable technical standards and project requirements
John Doe –
Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore.
eu fugiat nulla pariatur. voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore.
eu fugiat nulla pariatur. voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore.
eu fugiat nulla pariatur. voluptate velit esse cillum dolore eu fugiat nulla pariatur.